<?xml version="1.0" encoding="UTF-8"?>
<?xml-stylesheet type="text/xsl" href="https://www.stroyjurnal-asa.ru/lib/pkp/xml/oai2.xsl" ?>
<OAI-PMH xmlns="http://www.openarchives.org/OAI/2.0/"
	xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance"
	xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/
		http://www.openarchives.org/OAI/2.0/OAI-PMH.xsd">
	<responseDate>2026-07-06T06:55:15Z</responseDate>
	<request identifier="oai:ojs2.stroyjurnal-asa.ru:article/375" metadataPrefix="jats" verb="GetRecord">https://www.stroyjurnal-asa.ru/index.php/asa/oai</request>
	<GetRecord>
		<record>
			<header>
				<identifier>oai:ojs2.stroyjurnal-asa.ru:article/375</identifier>
				<datestamp>2026-05-20T07:30:16Z</datestamp>
				<setSpec>asa:ES</setSpec>
			</header>
			<metadata>
<article xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns="https://jats.nlm.nih.gov/publishing/1.1/" xml:lang="ru" article-type="research-article" dtd-version="1.1" specific-use="eps-0.1">
			<front>
			<journal-meta>
			
			
				
				
				<journal-id journal-id-type="publisher-id">asa</journal-id><journal-title-group>
			<journal-title xml:lang="ru">Строительство и техногенная безопасность</journal-title></journal-title-group>			<issn pub-type="ppub">2413-1873</issn>			<publisher><publisher-name>КФУ им. В.И. Вернадского</publisher-name></publisher>
		</journal-meta>
		<article-meta>
			<article-id pub-id-type="publisher-id">375</article-id>
			<article-categories><subj-group xml:lang="en"><subject>Environmental safety</subject></subj-group><subj-group xml:lang="ru"><subject>Экологическая безопасность</subject></subj-group></article-categories>
			<title-group><article-title xml:lang="ru">ЭНЕРГЕТИЧЕСКАЯ ЭФФЕКТИВНОСТЬ СОЛНЦЕЗАЩИТНЫХ УСТРОЙСТВ</article-title><trans-title-group xml:lang="en"><trans-title>ENERGY EFFICIENCY OF SUN PROTECTION DEVICES</trans-title></trans-title-group></title-group>
			<contrib-group content-type="author">
				<contrib contrib-type="author">
<name-alternatives>					<name>
						<surname>Дворецкий</surname>
						<given-names>А. Т.</given-names>
					</name>
					<name xml:lang="en">
						<surname>Dvoretskу</surname>
						<given-names>A. T.</given-names>
					</name>
</name-alternatives>					<xref ref-type="aff" rid="aff-1"/>
				</contrib>
			</contrib-group>
			<aff id="aff-1">
			<institution content-type="orgname">Крымский федеральный университет им В.И. Вернадского</institution>
			<institution content-type="orgname" xml:lang="en">Crimean Federal University named after V.I. Vernadsky</institution>
			</aff>
			<pub-date date-type="pub" publication-format="electronic">
				<day>29</day>
				<month>12</month>
				<year>2023</year>
			</pub-date>
				<issue seq="1">31(83)</issue><issue-id>85</issue-id><fpage>119</fpage>
				<lpage>126</lpage>
			<permissions>
				<copyright-statement>Copyright (c) 2026 </copyright-statement>
				<copyright-year>2026</copyright-year>
			</permissions>
			<self-uri>https://www.stroyjurnal-asa.ru/index.php/asa/article/view/375</self-uri>
			<abstract><p>Вопрос обеспечения комфортных условий жизнедеятельности человека лежит в основе создания и улучшения микроклимата помещения. Это может быть достигнуто так же за счёт энергетической эффективности солнцезащитных устройств. Этот вопрос актуален не только для холодного периода года, когда необходим обогрев помещений, но и для теплого периода. В холодный период интерес представляет результирующая тепловая энергия, которая есть разница между поступлением и потерей энергии через светопрозрачные конструкции. Для выбора стеклопакета учитывались поступающая солнечная радиация, наружная и внутренняя температуры. Климатические условия Москвы по значениям среднегодовой температуры и солнечной радиации 1400…1700 солнечных часов в году сравнимы с климатическими условиями Стокгольма, поэтому снижение годового потребления энергии на климатизацию помещения за счёт наружных солнцезащитных устройств в Москве может быть как в Стокгольме - 23%. По этим параметрам климата в Париже и Симферополе снижение годового потребления энергии на климатизацию помещения за счёт наружных солнцезащитных устройств в Симферополе больше, чем в Париже на 27,5%.</p>
<p>Предмет исследований: Энергетическая эффективность солнцезащитных конструкций и устройств.</p>
<p>Материалы и методы: Определение энергоэффективности солнцезащитных устройств на основе подобия климатических условий городов России и столиц европейских стран.</p>
<p>Результаты: Определено количество энергии, идущее на отопление, которое компенсируется солнечной энергией и количество солнечной энергии, экранируемой наружными солнцезащитными устройствами. Результаты этих расчётов и климатические параметры позволили определить снижение потребления энергии необходимое для климатизации здания в течении года.</p>
<p>Выводы: Грамотное использование солнцезащитных устройств позволяет существенно снизить потребление энергии на климатизацию помещения. Однако, в проектировании зданий недостаточно используются технологии с пассивным солнечным нагревом и охлаждением. Причины следующие: 1. Экономические факторы – в большинстве случаев новые технологии и решения дороже тех, которые уже применяются, хотя быстро окупаются (для низкоэнергетических зданий 5-7лет). 2. Отсутствие технических знаний, а также нежелание им обучаться. 3. Нежелание и неумение использовать «новые» технологии.</p></abstract><trans-abstract xml:lang="en"><p>The issue of ensuring comfortable living conditions for humans lies at the heart of creating and improving the indoor microclimate. This can also be achieved due to the energy efficiency of solar shading devices.</p>
<p>This issue is relevant not only for the cold period of the year, when heating of the premises is necessary, but also for the warm period. During the cold period, the resulting thermal energy is of interest, which is the difference between the energy gained and lost through translucent structures. To select a double-glazed window, incoming solar radiation, external and internal temperatures were taken into account.</p>
<p>Since the climatic conditions of Moscow are similar in terms of average annual temperature and solar radiation (1400 -1700 hours of sunshine per year) to the climatic conditions of Stockholm, the reduction in annual energy consumption for air conditioning of premises due to external sun-protection devices in Moscow is the same as in Stockholm - 23%. Based on these climate parameters in Paris and Simferopol, the reduction in annual energy consumption for room air conditioning due to external sun-protection devices in Simferopol is greater than in Paris (27.5%).</p>
<p>Subject of research: The subject of research is the energy efficiency of sun-protection structures and devices.</p>
<p>Materials and methods: The article proposes a determination of the energy efficiency of sun protection devices based on the similarity of climatic conditions of Russian cities and the capitals of European countries.</p>
<p>Results: The amount of energy spent on heating, which is compensated by solar energy, and the amount of solar energy screened by external solar shading devices were determined. The results of these calculations and climatic parameters made it possible to determine the reduction in energy consumption necessary to air-condition the building throughout the year.</p>
<p>Conclusions: Proper use of sun protection devices can significantly reduce energy consumption for room air conditioning. However, passive solar heating and cooling technologies are underutilized in building design. The reasons are as follows: 1. Economic factors - in most cases, new technologies and solutions are more expensive than those that are already in use, although they quickly pay for themselves (for low-energy buildings 5-7 years). 2. Lack of technical knowledge, as well as reluctance to learn it. 3. Reluctance and inability to use “new” technologies.</p></trans-abstract><kwd-group xml:lang="en"><title>Keywords</title><kwd>building air conditioning</kwd><kwd>climatic conditions</kwd><kwd>sun protection device</kwd><kwd>passive solar heating and cooling</kwd><kwd>resulting thermal energy</kwd><kwd>low-energy buildings</kwd></kwd-group><kwd-group xml:lang="ru"><title>Ключевые слова</title><kwd>климатизации здания</kwd><kwd>климатические условия</kwd><kwd>солнцезащитное устройство</kwd><kwd>пассивный солнечным нагрев и охлаждение</kwd><kwd>результирующая тепловая энергия</kwd><kwd>низкоэнергетические здания</kwd></kwd-group><counts><page-count count="8"/></counts>
		</article-meta>
	</front>
	<body><p>полный текст на сайте stroyjurnal-asa.ru</p></body>
	<back>
		<ref-list>
			<ref id="R1"><mixed-citation>David A. Bainbridge. Passive Solar Architecture. Heating, Cooling, Ventilation and Daylighting Using Nature Flows/ David A. Bainbridge, Ken Haggard// Chelsea Green Publishing – Vermont. 2011. 300 pages.</mixed-citation></ref>
			<ref id="R2"><mixed-citation>Alexander Dvoretsky, Ksenia Klevets. Heat Loss Reduction of Energy-Efficient Home by Buffer Areas/ MOTROL, Vol. 16, No 5. Lublin, Poland. 2014, C. 141-146.</mixed-citation></ref>
			<ref id="R3"><mixed-citation>Passive Solar Design Strategies: Guidelines for Home Building. Passive Solar Industries, Council National Renewable Energy Laboratory, Charles Eley Associates. Seattle, Washington. 1992. 85 pages.</mixed-citation></ref>
			<ref id="R4"><mixed-citation>Дворецкий А.Т., Митрофанова С.А., Клевец К.Н. Солнцезащита как элемент пассивной</mixed-citation></ref>
			<ref id="R5"><mixed-citation>низкоэнергетической архитектуры// «Строительство и техногенная безопасность» Спецвыпуск, Симферополь, 2022. С. 11-17.</mixed-citation></ref>
			<ref id="R6"><mixed-citation>Гагарин В.Г., Коркина Е.В., Шмаров И.А. и др. Расчеты теплопоступлений в здание от проникающей солнечной радиации за отопительный период/ Методическое пособие. Москва. 2017. 111 с.</mixed-citation></ref>
			<ref id="R7"><mixed-citation>Дворецкий А.Т., Клевец К.Н. Избыток тепловой энергии в системах пассивного солнечного нагрева здания// Строительство и реконструкция - Орёл. №5 (67), 2016. С. 79-86.</mixed-citation></ref>
			<ref id="R8"><mixed-citation>Sergeychuk O.V. Optimization of the Form of Energy Conservation Buildings // Motornizacja I energetyka rolnictwa. Lublin, 2008. – No 10A. pp. 121-130.</mixed-citation></ref>
			<ref id="R9"><mixed-citation>Solar shading for low energy building/European Solar Shading Organization/ Edition 1. 2012. 48 pages.</mixed-citation></ref>
		</ref-list>
	</back>
</article>			</metadata>
		</record>
	</GetRecord>
</OAI-PMH>
